PIG™ Latching Drum Lid with Fusible Plugs

For 55 gal. Steel Drums, FM-Approved, Bolt-Ring
As Low As $358.00
The only latching lid that meets NFPA 30 venting requirements helps you safely contain and lock flammable materials in a 55-gallon steel drum.   Read More 

PRICING (Based on quantity)

$378.00 $358.00
Pig Exclusive
This product has accessories — take a look 

Description

The only latching lid that meets NFPA 30 venting requirements helps you safely contain and lock flammable materials in a 55-gallon steel drum.
  • The only latching lid that satisfies NFPA 30 venting requirements
  • In a fire, 2" and 3/4" FM Approved nylon plugs melt to vent pressure and prevent drum bursting
  • Ideal for safe storage of flammable or combustible solids such as used rags and absorbents
  • Latching handle easily opens and closes with one hand
  • Nitrile gasket and locking mechanism seal lid to help reduce vapor emissions
  • Easy-access lid closes securely to help you meet haz-waste regs
  • Hinge stops keep funnel lid upright when open
  • Durable, chemical-resistant powder coat helps ensure long service life
  • Lockable latch helps prevent unauthorized access
  • Hinge pin is made for easy lid removal without loosening band around drum

Specifications

Special Feature FM-Approved
Style Hinged Lid w/ One-Hand Latch
Use With 55 gal. Steel Drums
Dimensions 23.25" W x 26.75" L x 4.375" H
Drum Mounting Bolt-Ring
Drum Size 55 gal.
Drum Type Steel Drum
Sold as 1 per box
Weight 25 lbs.
NSN (National Stock Number) DRM1065-BK - 8110-01-595-7372
DRM1065-RD - 8110-01-595-7372
DRM1065-YW - 8110-01-595-7372
# per Pallet 23
Composition Lid - Steel
Gasket - Nitrile
Bungs - Nylon
Padlockable Padlockable w/ .25" Shackle
UNSPSC 24112112
Pigalog® Page Number Page 304

Accessories for DRM1065

Reviews






Show All Based on 5 reviews





By John

8/16/2012

Drum lid

Drum lid is well constructed and works great. Be sure your drums have a 23 inch (+/-1/4") diameter opening for this to seal correctly.






By stephen

2/15/2012

Review for Latching Drum Lid with Fusable Plugs

Visually appealing, product performance excellent, just a bit difficult to operate with one hand. overall good rating






By Robert

12/21/2011

Great product.

Easy to install, easy to use, and great value. Delivered on time and will order more when needed. Would like to have seen a stainless steel version to purchase. I replaced some of the caps with safety features to address pressure and vacuum conditions depending on the drum lids application.






By Susan

9/13/2011

Latching Drum Lid

It makes it very easy to comply with the closed container rules for a drum that gets opened and closed a lot in a day.






By Robert

7/26/2011

Great Product

I have purchased this product in the past and just last week. Great product... you guys have the best stuff...

Additional Information

  • Chemical Compatibility for Nitrile gasket for PIG® Drum lids and funnels
  • PIG Latching Drum Lid (Steel) Instructions
  • 29 CFR 1910.106(e)(2)(i)
    Flammable liquids need to be stored in closed containers that are sealed by a "lid or other device" that does not allow liquids or vapors to escape.
  • 29 CFR 1910.134)(a)(1)
    A respirator shall be provided to each employee when such equipment is necessary to protect the health of such employee. The employer shall provide the respirators which are applicable and suitable for the purpose intended. The employer shall be responsible for the establishment and maintenance of a respiratory protection program, which shall include the requirements outlined in paragraph (c) of this section. The program shall cover each employee required by this section to use a respirator.
  • 29 CFR 1910.22(a)
    All places of employment "shall be kept clean and dry and in a sanitary condition" and floors shall be kept clean and dry.
  • 40 CFR 261.4
    Helps you comply with 40 CFR 261.4 requiring excluded solvent contaminated wipes to be accumulated and stored in closed containers while they are managed onsite.
  • 40 CFR 262.15
    Satellite Accumulation Areas allow generators of hazardous waste to accumulate as much as 55 gallons of hazardous waste or one quart of acutely hazardous waste in containers at or near the point of generation. The container must be kept closed when not in use, must be under the control of the operator generating the waste and must be properly labeled.
  • 40 CFR 262.16(b)(2)(iii)
    Small and Large Quantity Generators of hazardous waste must keep hazardous waste storage containers closed, except when adding or removing waste from the container.
  • 40 CFR 262.17(a)(1)(iv)
    Small and Large Quantity Generators of hazardous waste must keep hazardous waste storage containers closed, except when adding or removing waste from the container.
  • 40 CFR 264.1086(c)(1)(ii)
    Level one containers must have closure devices that, "form a continuous barrier over the container openings." When these closure devices are in place, there can be, "no visible holes, gaps or other open spaces into the interior of the container."
  • Certifications, Approvals and Ratings
  • NFPA Code 30

Contact Us